Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia
File version
Author(s)
Costa, F Da Silva
Sahota, D
Hyett, J
Mclennan, A
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
License
Abstract
Objective: To assess the quality of mean uterine artery (UtA) pulsatility index (PI) measurement in a first-trimester pre-eclampsia screening program. Methods: Consecutive women with a singleton pregnancy attending first-trimester screening for fetal chromosomal abnormalities also had combined screening for pre-eclampsia based on the Fetal Medicine Foundation (FMF) algorithm, at a large practice in Sydney, Australia, from May 2014 to February 2017. Distributions of mean UtA-PI multiples of the median (MoM) on a logarithmic scale were plotted in relation to the normal median with 95% CI for each operator and for each month. Central tendency and dispersion and cumulative sum charts were produced. Mean UtA-PI MoM values between 0.95 and 1.05 were considered ideal and those between 0.90 and 1.10 were considered acceptable. The screen-positive rates for preterm pre-eclampsia in different groups of sonographers according to their mean log 10 UtA-PI MoM were calculated and compared using the chi-square test. Results: A total of 21 010 women attended for first-trimester ultrasound and had screening for pre-eclampsia. The overall median UtA-PI MoM was 1.042 (interquartile range (IQR), 0.85–1.26). Of 46 sonographers, 42 (91.3%) performed more than 50 examinations and, of those, 41 (97.6%) measured UtA-PI within the acceptable range. Sonographers measuring UtA-PI MoM on average below 0.95 and those measuring it above 1.05 had, respectively, lower and higher screen-positive rates when compared with those with measurements within the 0.95–1.05 UtA-PI MoM interval (7.2% and 13.2% vs 11.2%, respectively, P < 0.001). Conclusion: UtA Doppler is measured well among trained operators when following an established protocol. While slight variations are expected, systematic error in this measurement impacts on the screen-positive rate. Therefore, a quality control process should be in place and retraining of staff may be required. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Journal Title
Ultrasound in Obstetrics & Gynecology
Conference Title
Book Title
Edition
Volume
53
Issue
2
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject
Reproductive medicine
Science & Technology
Life Sciences & Biomedicine
Acoustics
Obstetrics & Gynecology
Persistent link to this record
Citation
Rolnik, DL; Costa, FDS; Sahota, D; Hyett, J; Mclennan, A, Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia, Ultrasound in Obstetrics & Gynecology, 2019, 53 (2), pp. 245-250