Screw placement is everything: Risk factors for loss of reduction with volar locking distal radius plates
File version
Version of Record (VoR)
Author(s)
Black, Alyce
Davies, Jonathan
Buttner, Petra
Heal, Clare
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
AIM: To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates. METHODS: A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance. RESULTS: Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis. CONCLUSION: Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.
Journal Title
World Journal of Orthopedics
Conference Title
Book Title
Edition
Volume
9
Issue
10
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© The Author(s) 2018. Published by Baishideng Publishing Group Inc. his is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Item Access Status
Note
Access the data
Related item(s)
Subject
Orthopaedics
Science & Technology
Life Sciences & Biomedicine
Orthopedics
Loss of reduction
Volar locking distal radius plate
Persistent link to this record
Citation
Drobetz, H; Black, A; Davies, J; Buttner, P; Heal, C, Screw placement is everything: Risk factors for loss of reduction with volar locking distal radius plates, World Journal of Orthopedics, 2018, 9 (10), pp. 203-209