A handheld luminometer with sub-attomole limit of detection for distributed applications in global health

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Lebel, Paul
Elledge, Susanna
Wiener, Diane M
Jeyakumar, Ilakkiyan
Phelps, Maíra
Jacobsen, Axel
Huynh, Emily
Charlton, Chris
Puccinelli, Robert
Mondal, Prasenjit
Saha, Senjuti
Tato, Cristina M
Gómez-Sjöberg, Rafael
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)

Paul, Debjani

Date
2024
Size
File type(s)
Location
Abstract

Luminescence is ubiquitous in biology research and medicine. Conceptually simple, the detection of luminescence nonetheless faces technical challenges because relevant signals can exhibit exceptionally low radiant power densities. Although low light detection is well-established in centralized laboratory settings, the cost, size, and environmental requirements of high-performance benchtop luminometers are not compatible with geographically-distributed global health studies or resource-constrained settings. Here we present the design and application of a ~$700 US handheld, battery-powered luminometer with performance on par with high-end benchtop instruments. By pairing robust and inexpensive Silicon Photomultiplier (SiPM) sensors with a low-profile shutter system, our design compensates for sensor non-idealities and thermal drift, achieving a limit of detection of 1.6E-19 moles of firefly luciferase. Using these devices, we performed two pilot cross-sectional serology studies to assess sars-cov-2 antibody levels: a cohort in the United States, as well as a field study in Bangladesh. Results from both studies were consistent with previous work and demonstrate the device’s suitability for distributed applications in global health.

Journal Title

PLOS Global Public Health

Conference Title
Book Title
Edition
Volume

4

Issue

2

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2024 Lebel et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Item Access Status
Note
Access the data
Related item(s)
Subject

Public health

Persistent link to this record
Citation

Lebel, P; Elledge, S; Wiener, DM; Jeyakumar, I; Phelps, M; Jacobsen, A; Huynh, E; Charlton, C; Puccinelli, R; Mondal, P; Saha, S; Tato, CM; Gómez-Sjöberg, R, A handheld luminometer with sub-attomole limit of detection for distributed applications in global health, PLOS Global Public Health, 2024, 4 (2), pp. e0002766

Collections