Hemodynamic Response to Exercise and Head-Up Tilt of Patients Implanted With a Rotary Blood Pump: A Computational Modeling Study

No Thumbnail Available
File version
Author(s)
Lim, Einly
Salamonsen, Robert Francis
Mansouri, Mahdi
Gaddum, Nicholas
Mason, David Glen
Timms, Daniel L
Stevens, Michael Charles
Fraser, John
Akmeliawati, Rini
Lovell, Nigel Hamilton
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2015
Size
File type(s)
Location
License
Abstract

The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioPI or linear Starling-like control), as well as constant left atrial pressure ( P l a - ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a - control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT.

Journal Title

Artificial Organs

Conference Title
Book Title
Edition
Volume

39

Issue

2

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical engineering

Clinical sciences

Science & Technology

Life Sciences & Biomedicine

Engineering, Biomedical

Transplantation

Persistent link to this record
Citation

Lim, E; Salamonsen, RF; Mansouri, M; Gaddum, N; Mason, DG; Timms, DL; Stevens, MC; Fraser, J; Akmeliawati, R; Lovell, NH, Hemodynamic Response to Exercise and Head-Up Tilt of Patients Implanted With a Rotary Blood Pump: A Computational Modeling Study, Artificial Organs, 2015, 39 (2), pp. E24-E35

Collections