In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device
File version
Accepted Manuscript (AM)
Author(s)
Cooney, Helena
Diab, Sara
Anstey, Chris
Thom, Ogilvie
Fraser, John F
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
License
Abstract
Non-invasive cardiac output monitoring techniques provide high yield, low risk mechanisms to identify and individually treat shock in the emergency setting. The non-invasive ultrasonic cardiac output monitoring (USCOM) device uses an ultrasound probe applied externally to the chest; however limitations exist with previous validation strategies. This study presents the in vitro validation of the USCOM device against calibrated flow sensors and compares user variability in simulated healthy and septic conditions. A validated mock circulation loop was used to simulate each condition with a range of cardiac outputs (2–10 l/min) and heart rates (50–95 bpm). Three users with varying degrees of experience using the USCOM device measured cardiac output and heart rate by placing the ultrasound probe on the mock aorta. Users were blinded to the condition, heart rate and cardiac output which were randomly generated. Results were reported as linear regression slope (β). All users estimated heart rate in both conditions with reasonable accuracy (β = 0.86–1.01), while cardiac output in the sepsis condition was estimated with great precision (β = 1.03–1.04). Users generally overestimated the cardiac output in the healthy simulation (β = 1.07–1.26) and reported greater difficulty estimating reduced cardiac output compared with higher values. Although there was some variability between users, particularly in the healthy condition (P < 0.01), all estimations were within a clinically acceptable range. In this study the USCOM provided a suitable measurement of cardiac output and heart rate when compared with our in vitro system. It is a promising technique to assist with the identification and treatment of shock.
Journal Title
Journal of Clinical Monitoring and Computing
Conference Title
Book Title
Edition
Volume
30
Issue
1
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2015 Springer Science+Business Media New York. This is an electronic version of an article published in Journal of Clinical Monitoring and Computing, Volume 30, Issue 1, pp 69–75, 2016. Journal of Clinical Monitoring and Computing is available online at: http://link.springer.com/ with the open URL of your article.
Item Access Status
Note
Access the data
Related item(s)
Subject
Biomedical engineering
Medical devices
Clinical sciences