Effects of estrogen on the mechanical behavior of the human Achilles tendon in vivo

No Thumbnail Available
File version
Author(s)
Bryant, Adam L
Clark, Ross A
Bartold, Simon
Murphy, Aron
Bennell, Kim L
Hohmann, Erik
Marshall-Gradisnik, Sonya
Payne, Craig
Crossley, Kay M
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2008
Size
File type(s)
Location
License
Abstract

Effects of estrogen on the mechanical behavior of the human Achilles tendon in vivo. J Appl Physiol 105: 1035-1043, 2008. First published June 19, 2008; doi:10.1152/japplphysiol.01281.2007.-The purpose of this study was to elucidate the effect of normal fluctuating [nonmonophasic oral contraceptive pill (MOCP) users] and low, consistent (MOCP users) endogenous plasma estrogen levels on the strain behavior of the Achilles tendon in vivo. Twenty women (age 28.0 4.2 yr, height 1.67 0.07 m, mass 61.6 6.8 kg) who had been using the MOCP for at least 12 mo together with 20 matched women who were non-MOCP users (age 31.9 7.3 yr, height 1.63 0.05 m, mass 62.5 5.9 kg) participated in this study. Non-MOCP users were tested at the time of lowest (menstruation) and highest ( ovulation) estrogen, whereas MOCP users, who exhibited constant and attenuated endogenous estrogen levels, were tested at day 1 and day 14 of their cycle. At each test session, maximal isometric plantarflexion efforts were performed on a calf-raise apparatus while synchronous real-time ultrasonography of the triceps surae aponeurosis was recorded. Achilles tendon strain (%) was calculated by dividing tendon displacement during plantarflexion by resting tendon length. Repeatedmeasures ANOVA revealed a significant (P 0.05) main effect of subject group with significantly lower Achilles strain (25.5%) in the MOCP users compared with the non-MOCP users. In conclusion, acute fluctuations in plasma estrogen across the menstrual cycle in non-MOCP users did not alter the strain behavior of the Achilles tendon. Conversely, long-term exposure to attenuated estrogen in MOCP users resulted in a decrease in Achilles tendon strain, which is thought to be attributed to the effects of endogenous estrogen on collagen synthesis. These findings have a number of important functional and clinical implications.

Journal Title

Journal of Applied Physiology

Conference Title
Book Title
Edition
Volume

105

Issue

4

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

Self-archiving of the author-manuscript version is not yet supported by this journal. Please refer to the journal link for access to the definitive, published version or contact the authors for more information.

Item Access Status
Note
Access the data
Related item(s)
Subject

Biological sciences

Biomedical and clinical sciences

Exercise physiology

Persistent link to this record
Citation
Collections