The Accuracy of Digital Impressions versus Conventional Impressions in Neonates with Cleft Lip and/or Palate: A Laboratory-Based Study
File version
Version of Record (VoR)
Author(s)
Bakr, Mahmoud
Love, Robert
Idris, Ghassan
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
Cleft lip and palate (CL/P) are a common congenital craniofacial anomaly requiring precise impressions for effective treatment. Conventional impressions (CIs) pose challenges in neonates with CL/P due to their delicate oral anatomy. While digital impressions (DIs) are increasingly recognised for their potential benefits over conventional methods in dentistry, their accuracy and application in neonates with cleft lip and palate (CL/P) remain underexplored. This study aimed to assess the accuracy of DIs compared to CIs in neonates with CL/P, using alginate and putty materials as references. A laboratory-based case–control study was conducted, utilising soft acrylic models resembling neonatal mouths with CL/P. Alginate and putty impressions were obtained conventionally, while digital impressions were captured using an intraoral scanner (IOS). A total of 42 models were analysed, divided evenly into three groups, with each group comprising 14 models. Superimposition and surface discrepancy analyses were performed to evaluate impression accuracy. The results revealed no statistically significant differences between the digital and conventional impressions in their intra-arch measurements and surface discrepancies. The mean measurement values did not significantly differ among groups, with p values indicating no significant variations (p > 0.05), confirmed by an analysis of variance. High intra-examiner reliability with Intra Class Coefficient (ICC) values close to 1 indicated consistent measurements over time. The current study demonstrates that DIs are equally accurate as conventional alginate and putty impressions in neonates with cleft lip and palate, offering a viable and less invasive alternative for clinical practise. This advancement holds promise for improving the treatment planning process and enhancing patient comfort, particularly in vulnerable neonatal populations. Further research is warranted to explore the clinical implications and factors affecting DI accuracy in this population.
Journal Title
Children
Conference Title
Book Title
Edition
Volume
11
Issue
7
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Item Access Status
Note
Access the data
Related item(s)
Subject
Oral and maxillofacial surgery
Biomedical and clinical sciences
Paediatrics
Public health
Persistent link to this record
Citation
Unnikrishnan, J; Bakr, M; Love, R; Idris, G, The Accuracy of Digital Impressions versus Conventional Impressions in Neonates with Cleft Lip and/or Palate: A Laboratory-Based Study, Children, 2024, 11 (7), pp. 827