Shielding Analysis of High-Frequency Coaxial Transformers Used for Electric Vehicle On-Board Charging Systems

Loading...
Thumbnail Image
File version
Author(s)
Water, W
Lu, J
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2013
Size

658195 bytes

File type(s)

application/pdf

Location
License
Abstract

This paper introduces a high-frequency coaxial transformer (HFCT) with a power ef?ciency of >99.5% and an operational frequency between 100-300 kHz. The power rating of the HFCT can be easily scaled from 2.5 to 20 kW by adapting its simple symmetrical struc- ture. The introduced HFCT is suitable for use with converters in electric vehicle on-board charging systems. It easily ful?lls the design requirements of being lightweight, compact, and having a high power density and achieved a volume reduction of 75% in comparison with commercial products Furthermore, the electromagnetic interferences are increasing with the increased operating frequency, and an inserted copper Faraday shield is used to deal with this issue (an 80.6% reduction of intra-winding capacitance was achieved). A shielding analysis, with a focus on the insertion losses, is undertaken by utilizing ?nite element method based numerical techniques.

Journal Title

IEEE Transactions on Magnetics

Conference Title
Book Title
Edition
Volume

49

Issue

7

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2013 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Item Access Status
Note
Access the data
Related item(s)
Subject

Physical sciences

Engineering

Persistent link to this record
Citation
Collections