Avoiding Pre-Isolation Step in Exosome Analysis: Direct Isolation and Sensitive Detection of Exosomes Using Gold-Loaded Nanoporous Ferric Oxide Nanozymes

Loading...
Thumbnail Image
File version
Author(s)
Boriachek, Kseniia
Masud, Mostafa Kamal
Palma, Carlos
Hoang-Phuong, Phan
Yamauchi, Yusuke
Hossain, Md Shahriar A
Nam-Trung, Nguyen
Salomon, Carlos
Shiddiky, Muhammad JA
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2019
Size
File type(s)
Location
License
Abstract

Most of the current exosome-analysis strategies are time-consuming and largely dependent on commercial extraction kit-based preisolation step, which requires extensive sample manipulations, costly isolation kits, reagents, tedious procedures, and sophisticated equipment and is prone to bias/artifacts. Herein we introduce a simple method for direct isolation and subsequent detection of a specific population of exosomes using an engineered superparamagnetic material with multifunctional properties, namely, gold-loaded ferric oxide nanocubes (Au-NPFe2O3NC). In this method, the Au-NPFe2O3NC were initially functionalized with a generic tetraspanin (exosomes-associated) antibody (i.e., CD63) and dispersed in sample fluids where they work as “dispersible nanocarriers” to capture the bulk population of exosomes. After magnetic collection and purification, Au-NPFe2O3NC-bound exosomes were transferred to the tissue-specific, antibody-modified, screen-printed electrode. As a proof of principle, we used a specific placental marker, placenta alkaline phosphatase (PLAP), to detect exosomes secreted from placental cells. The peroxidase-like activity of Au-NPFe2O3NC was then used to accomplish an enzyme-linked immunosorbent assay (ELISA)-based sensing protocol for naked-eye observation along with UV–visible and electrochemical detection of PLAP-specific exosomes present in placental cell-conditioned media. We demonstrated excellent agreement in analytical performance for the detection of placental cell-derived exosomes (i.e., linear dynamic range, 103–107 exosomes/mL; limit of detection, 103 exosomes/mL; relative standard deviation (%RSD) of <5.5% for n = 3) using with and without commercial “total exosome isolation kit”-based preisolation step. We envisage that this highly sensitive, rapid, and inexpensive assay could be useful in quantifying specific populations of exosomes for various clinical applications, focusing on pregnancy complications.

Journal Title

ANALYTICAL CHEMISTRY

Conference Title
Book Title
Edition
Volume

91

Issue

6

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

This is the author-manuscript version of a Published Work that appeared in final form in Analytical Chemistry, © 2019 American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see 10.1021/acs.analchem.8b03619

Item Access Status
Note
Access the data
Related item(s)
Subject

Analytical chemistry

Other chemical sciences

Medical biochemistry and metabolomics

Chemical engineering

Persistent link to this record
Citation
Collections