A comparison of the effects of manual hyperinflation and ventilator hyperinflation on restoring end-expiratory lung volume after endotracheal suctioning: A pilot physiologic study

Loading...
Thumbnail Image
File version

Accepted Manuscript (AM)

Author(s)
Linnane, Matthew P
Caruana, Lawrence R
Tronstad, Oystein
Corley, Amanda
Spooner, Amy J
Barnett, Adrian G
Thomas, Peter J
Walsh, James R
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2019
Size
File type(s)
Location
Abstract

Purpose: Endotracheal suctioning (ES) of mechanically ventilated patients decreases end-expiratory lung volume (EELV). Manual hyperinflation (MHI) and ventilator hyperinflation (VHI) may restore EELV post-ES but it remains unknown which method is most effective. The primary aim was to compare the efficacy of MHI and VHI in restoring EELV post-ES.

Materials and methods: ES was performed on mechanically ventilated intensive care patients, followed by MHI or VHI, in a randomised crossover design. The washout period between interventions was 1 h. End-expiratory lung impedance (EELI), measured by electrical impedance tomography, was recorded at baseline, during ES, during hyperinflation and 1, 5, 15 and 30 min post-hyperinflation.

Results: Nine participants were studied. ES decreased EELI by 1672z (95% CI, 1204 to 2140) from baseline. From baseline, MHI increased EELI by 1154z (95% CI, 977 to 1330) while VHI increased EELI by 769z (95% CI, 457 to 1080). Five minutes post-VHI, EELI remained 528z (95% CI, 4 to 1053) above baseline. Fifteen minutes post-MHI, EELI remained 351z (95% CI, 111 to 592) above baseline. At subsequent time-points, EELI returned to baseline.

Conclusions: MHI and VHI effectively restore EELV above baseline post-ES and should be considered post suctioning.

Journal Title

Journal of Critical Care

Conference Title
Book Title
Edition
Volume

49

Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2019 Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence, which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.

Item Access Status
Note
Access the data
Related item(s)
Subject

Clinical sciences

Nursing

Science & Technology

Life Sciences & Biomedicine

Critical Care Medicine

General & Internal Medicine

Ventilator hyperinflation

Persistent link to this record
Citation

Linnane, MP; Caruana, LR; Tronstad, O; Corley, A; Spooner, AJ; Barnett, AG; Thomas, PJ; Walsh, JR, A comparison of the effects of manual hyperinflation and ventilator hyperinflation on restoring end-expiratory lung volume after endotracheal suctioning: A pilot physiologic study, Journal of Critical Care, 2019, 49, pp. 77-83

Collections