Comparison of Supraglottic Airway Devices With Endotracheal Intubation in Low-Risk Patients for Cesarean Delivery: Systematic Review and Meta-analysis

No Thumbnail Available
File version
Author(s)
White, LD
Thang, C
Hodsdon, A
Melhuish, TM
Barron, FA
Godsall, MG
Vlok, R
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2020
Size
File type(s)
Location
License
Abstract

BACKGROUND: The safety and adverse event rate of supraglottic airway (SGA) devices for cesarean delivery (CD) is poorly characterized. The primary aims of this review were to determine whether the first-pass success was higher and time to insertion for SGA was faster than endotracheal intubation for elective CD. The secondary aim was to determine the airway-related adverse event rate associated with SGA use compared to endotracheal intubation in elective CD under general anesthesia (GA). METHODS: Six databases were systematically searched until September 2019. Included studies reported on the use of SGA in comparison to endotracheal tube intubation. A comparative meta-analysis between SGA and endotracheal intubation was performed using RevMan 5.3 software. Dichotomous outcomes were reported using an odds ratio (OR) with 95% confidence interval (CI). The results for continuous outcomes were reported using a weighted mean difference (WMD) with 95% CI. RESULTS: Fourteen studies with 2236 patients compared SGA and endotracheal intubation. Overall, there was no statistically significant difference in first-attempt success rate (OR = 1.92; 95% CI, 0.85-4.32; I2 = 0%; P =.44). There was no clinically significant difference in time to insertion (WMD =-15.80 seconds; 95% CI,-25.30 to-6.31 seconds; I2= 100%; P =.001). Similarly, there was no difference in any adverse event rate except sore throat which was reduced with the use of an SGA (OR = 0.16; 95% CI, 0.08-0.32; I2= 53%; P <.001). CONCLUSIONS: Despite the reasonable insertion success rate and safety profile of SGAs demonstrated in this meta-analysis, the analysis remains underpowered and therefore inconclusive. At present, further studies are required before the use of an SGA as the first-line airway for an elective CD can be recommended.

Journal Title

Anesthesia and Analgesia

Conference Title
Book Title
Edition
Volume

131

Issue

4

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Clinical sciences

Neurosciences

Persistent link to this record
Citation

White, LD; Thang, C; Hodsdon, A; Melhuish, TM; Barron, FA; Godsall, MG; Vlok, R, Comparison of Supraglottic Airway Devices With Endotracheal Intubation in Low-Risk Patients for Cesarean Delivery: Systematic Review and Meta-analysis, Anesthesia and Analgesia, 2020, 131 (4), pp. 1092-1101

Collections