High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics
File version
Accepted Manuscript (AM)
Author(s)
Kang, Xiaoyue
Yuan, Dan
de Villiers, Belinda
Mak, Johnson
Nguyen, Nam-Trung
Zhang, Jun
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
White blood cells (WBCs) are a crucial component of the human immune system. WBCs contain invaluable information about the health status of the human body. Therefore, separating WBCs is indispensable for the diagnosis of many diseases in clinical setting. The low ratio of WBCs to red blood cells in whole blood has made the isolation of WBCs challenging. As the conventional single-stage microfluidic technology cannot provide sufficient separation purity. We used a cascaded inertial microfluidic chip by consecutively connecting two sinusoidal channels to enhance the purity of WBCs after single processing. The improvement was in part due to the diversion of the sample at the end of the first stage separation, resulting in a lower flow rate in the second stage of processing within the cascaded device. We embedded concave micro-obstacles in sinusoidal channels to adjust their effective working flow rate range and enable the proper operation of both channels simultaneously. Using polystyrene beads mixture (5 and 10 μm) with a primary ratio of 1,000 to 1, a single processing step through our cascaded chip improved the purity of 10-μm particles with more than three orders of magnitude of enrichment (from 0.08% to 99.83%) with a flow rate of 560 μl/min (Re = 77). Using diluted whole blood (×1/10), we achieved 307-fold enrichment of WBCs (0.14% to 43.017%) in a single process which was accompanied with ∼3 orders of magnitude background removal of RBCs (from 4.8×108 to 5.7×105 counts/mL). This cascaded manner chip has the capacity to achieve high-efficiency separation of blood cells for clinical diagnosis.
Journal Title
Talanta
Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2024 Published by Elsevier B.V. http://creativecommons.org/licenses/by/4.0/
Item Access Status
Note
This publication has been entered in Griffith Research Online as an advance online version.
Copyright permissions for this publication were identified from the publisher's website at https://doi.org/10.1016/j.talanta.2024.127200
Access the data
Related item(s)
Subject
Biomedical and clinical sciences
Biochemistry and cell biology
Analytical chemistry
Persistent link to this record
Citation
Cha, H; Kang, X; Yuan, D; de Villiers, B; Mak, J; Nguyen, N-T; Zhang, J, High-efficient white blood cell separation from whole blood using cascaded inertial microfluidics, Talanta, 2024, pp. 127200