Infection Associated With Invasive Devices in Pediatric Health Care: A Meta-analysis

Loading...
Thumbnail Image
Files
Takashima9422672.pdf
Embargoed until 2024-12-28
File version

Accepted Manuscript (AM)

Author(s)
Takashima, Mari
Hyun, Areum
Xu, Grace
Lions, Adriana
Gibson, Victoria
Cruickshank, Marilyn
Ullman, Amanda
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2024
Size
File type(s)
Location
License
Abstract

CONTEXT Indwelling invasive devices inserted into the body for extended are associated with infections.

OBJECTIVE This study aimed to estimate infection proportion and rates associated with invasive devices in pediatric healthcare.

DATA SOURCES Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched.

STUDY SELECTION Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) postinsertion infection complications, and (4) published in English, were included.

DATA EXTRACTION Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used.

MAIN OUTCOMES AND MEASURES Device local, organ, and bloodstream infection (BSIs) pooled proportion and incidence rate (IR) per-1000-device-days per device type were reported.

RESULTS A total of 116 studies (61 554 devices and 3 632 364 device-days) were included. The highest number of studies were central venous access devices associated BSI (CVAD-BSI), which had a pooled proportion of 8% (95% confidence interval [CI], 6–11; 50 studies) and IR of 0.96 per-1000-device-days (95% CI, 0.78–1.14). This was followed by ventilator-associated pneumonia in respiratory devices, which was 19% (95% CI, 14–24) and IR of 14.08 per-1000-device-days (95%CI, 10.57–17.58).

CONCLUSIONS Although CVAD-BSI and ventilator associated pneumonia are well-documented, there is a scarcity of reporting on tissue and local organ infections. Standard guidelines and compliance initiatives similar to those dedicated to CVADs should be implemented in other devices in the future.

Journal Title

Hospital Pediatrics

Conference Title
Book Title
Edition
Volume

14

Issue

1

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

This work is covered by copyright. You must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a specified licence, refer to the licence for details of permitted re-use. If you believe that this work infringes copyright please make a copyright takedown request using the form at https://www.griffith.edu.au/copyright-matters.

Item Access Status
Note
Access the data
Related item(s)
Subject

Paediatrics

Health services and systems

Persistent link to this record
Citation

Takashima, M; Hyun, A; Xu, G; Lions, A; Gibson, V; Cruickshank, M; Ullman, A, Infection Associated With Invasive Devices in Pediatric Health Care: A Meta-analysis, Hospital Pediatrics, 2024, 14 (1), pp. e42-e56

Collections