An Evaluation on Initial Deficiency of Left Ventricular Systolic Function in Patients with Systemic Hypertension by Speckle Tracking Echocardiography

No Thumbnail Available
File version
Author(s)
Nguyen, DT
Nguyen, VA
Do, LD
Doan, N
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2020
Size
File type(s)
Location

Ho Chi Minh, Vietnam

License
Abstract

Background Speckle tracking echocardiography 2D (STE 2D), a new technology, allows rapid and accurate analysis of regional and global left ventricular systolic function. Aim The aim of this study was to assess subclinical left ventricular systolic dysfunction in the patients with systemic hypertension with preserved ejection fraction by using STE 2D. Methods 2D echocardiography images of left ventricular were acquired in six sections-apical 4-chamber, 2-chamber, 3-chamber, parasternal short axis at the basal, mid, and apical levels in 194 subjects (151 hypertensive patients and 43 healthy controls). The images were analysed by QLAB software version 9.0. Long, circumferential and radial strain were quantified in 18-segments. Result Peak systolic long strain, circumferential strain, radial strain and longitudinal-circumferential systolic index were markedly decreased in patients with systemic hypertension comparing with control group (−11.57 ± 2.37% vs. −16.52 ± 1.19%; −13.52 ± 4.97% vs. −17.92 ± 2.39%; 10.24 ± 3.4% vs. 12.33 ± 1.94%; −12.55 ± 2.83% vs. −17.22 ± 1.44%, p < 0.001). Besides, the average of systolic blood pressure in normal longitudinal-circumferential systolic index group is lower than abnormal that group (127.93 ± 9.02 mmHg vs. 139.92 ± 12.51 mmHg, p < 0.001) and the average of systolic blood pressure in normal systolic index group is lower than abnormal that group (128.57 ± 8.1 mmHg vs. 141.96 ± 12.39 mmHg, p < 0.001). Conclusion although left ventricular ejection fraction is normal by conventional echocardiography, there is an early decline in systolic function by STE method and mean systolic blood pressure in the groups with normal systolic strain parameters are lower than that with abnormal strain parameters.

Journal Title
Conference Title

7th International Conference on the Development of Biomedical Engineering in Vietnam (BME7)

Book Title
Edition
Volume

69

Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical engineering

Persistent link to this record
Citation

Nguyen, DT; Nguyen, VA; Do, LD; Doan, N, An Evaluation on Initial Deficiency of Left Ventricular Systolic Function in Patients with Systemic Hypertension by Speckle Tracking Echocardiography, 7th International Conference on the Development of Biomedical Engineering in Vietnam (BME7), 2020, 69, pp. 591-595