The effects of higher temperature setpoints during summer on office workers' cognitive load and thermal comfort

Loading...
Thumbnail Image
File version

Accepted Manuscript (AM)

Author(s)
Zhang, Fan
Haddad, Shamila
Nakisa, Bahareh
Rastgoo, Mohammad Naim
Candido, Christhina
Tjondronegoro, Dian
de Dear, Richard
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2017
Size
File type(s)
Location
Abstract

Typical commercial lease agreements in Australia stipulate 22.5 ± 1.5 °C in summer as the acceptable thermal condition that buildings have to meet, even though the overcooling incurs excessive and unnecessary energy use, gas emissions and financial expense. An argument that backs up this practice asserts that office workers' productivity and comfort will be jeopardised outside this temperature range. This paper investigated whether the office environments with a practical higher temperature setpoint can still be cognitively efficient and comfortable for office workers. In a controlled climate chamber, 26 office workers experienced the typical summer indoor temperature condition in Australia (22 °C) followed by the condition with a higher temperature setpoint (25 °C). In both conditions, subjects were required to fulfil Cambridge Brain Science (CBS) cognitive performance tests, NASA Task Load Index (NASA-TLX), and thermal comfort and air quality questionnaires. Meanwhile, participants' electroencephalogram (EEG) and heart rate (HR) were recorded under three different difficulty levels of Paced Auditory Serial Addition Tests (PASAT). Results showed that CBS test scores were not significantly affected by temperature; a higher temperature of 25 °C incurred a significantly reduced cognitive load for subjects, as has been observed by NASA-TLX, but probably due to the learning effect; the comparison between EEG and HR features during different temperatures did not show any significant difference. Participants' thermal comfort was not significantly jeopardized by the 3 °C temperature setback either. Results from this study favourably support a practical setback of temperature setpoints in Australian office buildings during summer.

Journal Title

Building and Environment

Conference Title
Book Title
Edition
Volume

123

Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2017 Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.

Item Access Status
Note
Access the data
Related item(s)
Subject

Architecture

Building

Other built environment and design not elsewhere classified

Built environment and design

Engineering

Persistent link to this record
Citation
Collections