Comparability and accuracy of time of wetness sensing methods relevant for atmospheric corrosion

No Thumbnail Available
File version
Author(s)
Schindelholz, E
Kelly, RG
Cole, IS
Ganther, WD
Muster, TH
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2013
Size
File type(s)
Location
License
Abstract

The performance of three time of wetness (TOW) determination methods during outdoor exposure was examined. Two impedance-based TOW sensor types, RH, and temperature sensors were exposed to coastal marine and laboratory environments for up to three months. The sensor and ISO 9223 methods examined provided incomparable estimates. Inaccuracy of the ISO method originated from a humidity threshold well above the drying point of deposited aerosols and differences between surface and ambient RH. TOW sensor accuracy was linked to electrode configuration. Small electrode spacing was demonstrated to be required to capture the range of wetting events of importance to atmospheric corrosion.

Journal Title

Corrosion Science

Conference Title
Book Title
Edition
Volume

67

Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Civil engineering

Materials engineering

Materials engineering not elsewhere classified

Mechanical engineering

Persistent link to this record
Citation
Collections