Effect of aortic cannulation depth on air emboli transport during cardiopulmonary bypass: A computational study

No Thumbnail Available
File version
Author(s)
Ho, Raymond
McDonald, Charles
Pauls, Jo P
Li, Zhiyong
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2022
Size
File type(s)
Location
License
Abstract

Introduction: Varying the insertion depth of the aortic cannula during cardiopulmonary bypass (CPB) has been investigated as a strategy to mitigate cerebral emboli, yet its effectiveness associated with CPB flow is not fully understood. We compared different arterial cannula insertion depths and pump flow influencing air microemboli entering the aortic arch branch arteries (AABA). Methods: A computational approach used a patient-specific aorta model to evaluate four cannula locations at (1) proximal arch, (2) mid arch, (3) distal arch, and (4) descending aorta. We injected 0.1 mm microemboli (N=720) at 2 and 5 L/min and assessed the embolic load and the particle averaged transit times (entering the AABA. Results: Location 4 had the lowest embolic load (2 L/min: N= 63) and (5 L/min: N= 54) compared to locations 1 to 3 in the range of (N= 118 to 116 at 2 L/min:) and (N= 92 to 146 at 5 L/min). There was no significant difference between 2 L/min and 5 L/min (p = 0.31), despite 5 L/min attaining a lower mean (±standard deviation) than 2 L/min (38.0±23.4 vs 44.5±21.1), respectively. Progressing from location 1 to 4, increased 3.11s -7.40 s at 2 L/min and 1.81s -4.18s at 5 L/min. Conclusion: It was demonstrated that the elongated cannula insertion length resulted in lower embolic loads, particularly at a higher flow rate. The numerical results suggest that CPB management could combine active flow variation with improving cannula performance and provide a foundation for a future experimental and clinical investigation to reduce surgical cerebral air microemboli.

Journal Title

Perfusion

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note

This publication has been entered in Griffith Research Online as an advanced online version.

Access the data
Related item(s)
Subject

Cardiology (incl. cardiovascular diseases)

Science & Technology

Life Sciences & Biomedicine

Cardiac & Cardiovascular Systems

Peripheral Vascular Disease

Cardiovascular System & Cardiology

Persistent link to this record
Citation

Ho, R; McDonald, C; Pauls, JP; Li, Z, Effect of aortic cannulation depth on air emboli transport during cardiopulmonary bypass: A computational study, Perfusion, 2022

Collections