The development of the Western Australian Haemodialysis Vascular Access Complexity instrument

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Coventry, Linda L
Hosking, Jon
Coral, Evelyn
Jenkins, Mark
Salgado Kent, Chandra P
Chan, Doris
Lim, Wai
Twigg, Diane E
Rickard, Claire M
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2021
Size
File type(s)
Location
Abstract

BACKGROUND: The Western Australian Haemodialysis Vascular Access Classification instrument was developed to classify the cannulation complexity of the arteriovenous fistula or arteriovenous graft as simple, challenging, or complex. Although the instrument was developed by experts in haemodialysis nursing, the instrument had not undergone formal validity or reliability testing. OBJECTIVES: Evaluate the Western Australian Haemodialysis Vascular Access Classification instrument for content validity, interrater and test-retest reliability. DESIGN: Prospective cohort study. PARTICIPANTS: Content validity was assessed by haemodialysis nursing experts (n = 8). The reliability testing occurred in one in-centre and one satellite haemodialysis unit in Western Australia from September to November 2019. Reliability testing was performed by 38 haemodialysis nurses in 67 patients receiving haemodialysis and 247 episodes of cannulation. MEASUREMENTS: Interrater and test-retest reliability assessment was conducted using κ, adjusted κ, Bland-Altman plots, intraclass correlation coefficient and Pearson's correlation coefficient. RESULTS: The final version of the instrument (n = 20 items) had individual item-level content validity indices ranging from 0.625 to 1.00 with a scale-level content validity index of 0.89. For both interrater (n = 172 pairs) and test-retest (n = 101 pairs), most individual variables had excellent adjusted κ (n = 33 variables), some fair to good agreement (n = 6 variables) and one variable with poor agreement. The classification of simple, challenging and complex demonstrated adjusted κ of fair to good, to excellent agreement for interrater reliability with lower levels of agreement for test-retest reliability. CONCLUSIONS: This instrument may be used to match a competency-assessed nurse to perform the cannulation thereby minimising the risk of missed cannulation and trauma.

Journal Title

Journal of Renal Care

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2021 The Authors. Journal of Renal Care published by John Wiley & Sons Ltd on behalf of European Dialysis & Transplant Nurses Association/European Renal Care Association. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Item Access Status
Note

This publication has been entered as an advanced online version in Griffith Research Online.

Access the data
Related item(s)
Subject

Clinical sciences

Nursing

Health services and systems

Public health

cannulation-related complications

haemodialysis

instrument development

kidney failure

reliability and validity

Persistent link to this record
Citation

Coventry, LL; Hosking, J; Coral, E; Jenkins, M; Salgado Kent, CP; Chan, D; Lim, W; Twigg, DE; Rickard, CM, The development of the Western Australian Haemodialysis Vascular Access Complexity instrument, Journal of Renal Care, 2021

Collections