Retinal differential light sensitivity variation across the macula in healthy subjects: Importance of cone separation and loci eccentricity

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Sampson, DM
Roshandel, D
Chew, AL
Wang, Y
Stevenson, PG
Cooper, MN
Ong, E
Wong, L
La, J
Alonso-Caneiro, D
Chelva, E
Khan, JC
Sampson, DD
Chen, FK
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2021
Size
File type(s)
Location
Abstract

Purpose: Microperimetry measures differential light sensitivity (DLS) at specific retinal locations. The aim of this study is to examine the variation in DLS across the macula and the contribution to this variation of cone distribution metrics and retinal eccentricity. Methods: Forty healthy eyes of 40 subjects were examined by microperimetry (MAIA) and adaptive optics imaging (rtx1). Retinal DLS was measured using the grid patterns: foveal (2°–3°), macular (3°–7°), and meridional (2°–8° on horizontal and vertical meridi-ans). Cone density (CD), distribution regularity, and intercone distance (ICD) were calcu-lated at the respective test loci coordinates. Linear mixed-effects regression was used to examine the association between cone distribution metrics and loci eccentricity, and retinal DLS. Results: An eccentricity-dependent reduction in DLS was observed on all MAIA grids, which was greatest at the foveal-parafoveal junction (2°–3°) (−0.58 dB per degree, 95% confidence interval [CI]; −0.91 to −0.24 dB, P < 0.01). Retinal DLS across the meridional grid changed significantly with each 1000 cells/deg2 change in CD (0.85 dB, 95% CI; 0.10 to 1.61 dB, P = 0.03), but not with each arcmin change in ICD (1.36 dB, 95% CI; −2.93 to 0.20 dB, P = 0.09). Conclusions: We demonstrate significant variation in DLS across the macula. Topographical change in cone separation is an important determinant of the variation in DLS at the foveal-parafoveal junction. We caution the extrapolation of changes in DLS measurements to cone distribution because the relationship between these variables is complex. Translational Relevance: Cone density is an independent determinant of DLS in the foveal-parafoveal junction in healthy eyes.

Journal Title

Translational Vision Science and Technology

Conference Title
Book Title
Edition
Volume

10

Issue

6

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© The Author(s) 2021. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International (CC BY-NC-ND 4.0) License, which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.

Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical and clinical sciences

Ophthalmology and optometry not elsewhere classified

Persistent link to this record
Citation

Sampson, DM; Roshandel, D; Chew, AL; Wang, Y; Stevenson, PG; Cooper, MN; Ong, E; Wong, L; La, J; Alonso-Caneiro, D; Chelva, E; Khan, JC; Sampson, DD; Chen, FK, Retinal differential light sensitivity variation across the macula in healthy subjects: Importance of cone separation and loci eccentricity, Translational Vision Science and Technology, 2021, 10 (6), pp. 16-16

Collections