Accuracy of a Qsofa Based Sepsis Screening Tool
File version
Accepted Manuscript (AM)
Author(s)
Marshall, Andrea P
Walker, Rachel
Palizas, Fernando
Aitken, Leanne M
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Adelaide, Australia
Abstract
Introduction: Early recognition of sepsis is vital to initiate timely treatment. The quick Sequential [Sepsisrelated] Organ Failure Assessment (qSOFA) has been proposed to identify sepsis outside the critical care setting. However there is limited evidence regarding its accuracy in the acute medical-surgical context. Objectives: The aim of this study was to test the diagnostic accuracy of a sepsis-screening tool that incorporated qSOFA (respiratory rate ≥22, altered mentation and systolic blood pressure ≤90mmHg) and the presence of confirmed/suspected infection in general hospitalised patients. Methods: An interrupted time series study was conducted in 2017 in a private hospital in Buenos Aires. Screening was positive where the qSOFA was ≥2 in patients with a confirmed or suspected infection. Screening tool performance was compared to the discharge diagnosis assessed by an experienced intensivist blinded to screening tool performance. Comorbidities were assessed with the Charlson Comorbidity Index (CCI). Descriptive statistics and accuracy tests were conducted with SPSS® Version 25. Results: 434 patients with a median (IQR) age 70(31) years were included. The majority were female (n=239; 55.0%); 272 (62.7%) were medical patients with a median (IQR) CCI 2(3). Patients stayed a median (IQR) of 4(3) days in hospital, 38 (8.8%) required intensive care for 1.4 (2 days); 12 (3%) died. The most common sources of confirmed/suspected infection were pulmonary (79, 18.2%), skin/soft tissue (44, 10.1%) and urinary (42, 9.7%). Eighty-two patients (18.9%) had a qSOFA ≥2; 58 (13.4%) were screened positive. Diagnosis at discharge were sepsis (15, 3.5%), infection (153, 35.3%) and other (260, 59.9%). Accuracy tests of the screening tool resulted in 60.0% sensitivity, 88.9% specificity, 16.4% positive and 98.4% negative predictive values. Conclusion(s): While the screening tool performed moderately well ruling-out non-septic patients, sensitivity was modest, with poor performance in predicting sepsis.
Journal Title
Conference Title
AUSTRALIAN CRITICAL CARE
Book Title
Edition
Volume
32
Issue
Supplement 1
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2019 Australian College of Critical Care Nurses Ltd. Published by Elsevier Australia. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence (http://creativecommons.org/licenses/by-nc-nd/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.
Item Access Status
Note
Access the data
Related item(s)
Subject
Clinical sciences
Nursing
Science & Technology
Life Sciences & Biomedicine
Critical Care Medicine
General & Internal Medicine
Persistent link to this record
Citation
Alberto, L; Marshall, AP; Walker, R; Palizas, F; Aitken, LM, Accuracy of a Qsofa Based Sepsis Screening Tool, Australian Critical Care, 2019, 32, pp. S1-S1