A Proposed In Vitro Methodology for Assessing the Accuracy of Three-Dimensionally Printed Dental Models and the Impact of Storage on Dimensional Stability
File version
Version of Record (VoR)
Author(s)
Granatelli, Joshua
Alifui-Segbaya, Frank
Drake, Laura
Smith, Derek
Ahmed, Khaled
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
The objective of this study was to propose a standardised methodology for assessing the accuracy of three-dimensional printed (3DP) full-arch dental models and the impact of storage using two printing technologies. A reference model (RM) comprising seven spheres was 3D-printed using digital light processing (MAX UV, MAX) and stereolithography (Form 2, F2) five times per printer. The diameter of the spheres (n = 35) represented the dimensional trueness (DT), while twenty-one vectors (n = 105) extending between the sphere centres represented the full-arch trueness (FT). Samples were measured at two (T1) and six (T2) weeks using a commercial profilometer to assess their dimensional stability. Significant (p < 0.05) contraction in DT occurred at T1 and T2 with a medium deviation of 108 µm and 99 µm for MAX, and 117 µm and 118 µm for F2, respectively. No significant (p > 0.05) deviations were detected for FT. The detected median deviations were evenly distributed across the arch for MAX at <50 µm versus F2, where the greatest error of 278 µm was in the posterior region. Storage did not significantly impact the model’s DT in contrast to FT (p < 0.05). The proposed methodology was able to assess the accuracy of 3DP. Storage significantly impacted the full-arch accuracy of the models up to 6 weeks post-printing.
Journal Title
Applied Sciences
Conference Title
Book Title
Edition
Volume
11
Issue
13
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Item Access Status
Note
Access the data
Related item(s)
Subject
Materials engineering
Dentistry
Persistent link to this record
Citation
Lin, LH; Granatelli, J; Alifui-Segbaya, F; Drake, L; Smith, D; Ahmed, K, A Proposed In Vitro Methodology for Assessing the Accuracy of Three-Dimensionally Printed Dental Models and the Impact of Storage on Dimensional Stability, Applied Sciences, 2021, 11 (13), pp. 5994