Impedance cardiography estimate of the Q˙‐V˙O2 relationship in pulmonary hypertension

No Thumbnail Available
File version
Author(s)
Aitken, C
Lin, A
Seale, H
Feenstra, J
Trotter, M
Sabapathy, S
Walsh, J
Morris, N
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2020
Size
File type(s)
Location

Melbourne, Australia

License
Abstract

Introduction/Aim. The assessment of cardiac function, specifically cardiac output(Q˙), is one of the most robust indicators of right ventricular function and prognosis in pulmonary arterial hypertension (PH). Impedance cardiography (IC), is non‐invasive, easily accessible and can be used at rest and exercise. Preliminary studies, have suggested IC estimates of Q˙ during exercise may be inaccurate(1). One indirect method of validation is to examine the relationship between Q˙ and oxygen uptake(V˙O2) during exercise, which is well established. The aim of this study was to investigate the Q˙‐V˙O2 relationship in a group of PH participants through IC.

Method. In this preliminary study, 5 medically stable individuals with PH(WHO Functional class II‐III) were recruited. All participants completed an incremental exercise test (CPET), to establish peak exercise capacity and on a separate day a submaximal CPET at 30 and 60% of their respective peak workload. During exercise Q˙ was measured using IC (PhysioFlow,) and V˙O2 measured using open circuit spirometry (Metamax) simultaneously. The Q˙‐V˙O2 was estimated per participant using resting and exercise data.

Results. The mean peak workload for the group was 91 ± 20 W. During the submaximal exercise test, there was a significant increase in Q˙(Rest: 5.2 ± 1.1; 30%: 7.4 ± 2.0; 60%: 10.2 ± 3.8 L.min‐1), V˙O2(Rest: 0.33 ± 0.06; 30%: 0.68 ± 0.04; 60%:1.03 ± 0.14 L.min‐1), heart rate(Rest: 74 ± 17; 30%: 94 ± 16, 60%: 113 ± 17 beats.min‐1) and stroke volume(Rest: 76.9 ± 38.4, 30%: 83.4 ± 39.3, 60% 95.8 ± 51.2 mL‐1). The mean slope of the Q˙‐V˙O2 relationship was 5.9 ± 4.1 (range 1.8‐10.8) which compares favourably with the mean slope from previous studies of 5.5 ± 0.5(2).

Conclusion. The results of this preliminary study suggest that when Q˙ is measured using IC, the Q˙‐V˙O2 relationship was similar to that reported by others. However, there was marked variance in the response and further studies are warranted in the PH population.

Journal Title
Conference Title

Respirology

Book Title
Edition
Volume

25

Issue

S1

Thesis Type
Degree Program
School
DOI
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical and clinical sciences

Health sciences

Science & Technology

Life Sciences & Biomedicine

Respiratory System

Impedance Cardiography

Cardiac Output

Persistent link to this record
Citation

Aitken, C; Lin, A; Seale, H; Feenstra, J; Trotter, M; Sabapathy, S; Walsh, J; Morris, N, Impedance cardiography estimate of the Q˙‐V˙O2 relationship in pulmonary hypertension, Respirology, 2020, 25, pp. 209-209